RS485

30 devices per bus, max. 100 devices

Power reduction

RS485

Hardware

Connect the inverters to each other using a patch cable.

Cut open the cable from the last inverter to the e.manager and connect the individual wires to the e.manager as follows.

e.manager terminal A <=> PIN 3 (yellow-white)
e.manager terminal B <=> PIN 6 (yellow)

Alternatively via the terminal block

e.manager terminal A <=> PIN 2 RX/TX B(+)
e.manager terminal B <=> PIN 3 RX/TX A(-)

 

Software

No settings are required for UniLynx inverters.

Password

Enter the password 1761. The display shows “Security level: 1”

Setup
    Security

No settings are required for UniLynx inverters.

Device address

For the address, enter a unique address between 1 and 32. Set the network and subnet to 1.

  • Network: 1
  • Subnet: 1
  • Address: X
Setup
    Communication setup
        ComLynx setup

After each change, restart the inverter on both the AC and DC side.