With the e.manager, you can connect your wind turbine to direct marketing (direct marketing of electricity). The e.manager supports all common direct marketers. Thanks to the integrated OpenVPN connection, no external OpenVPN router is required.
Power measurement
The e.manager offers various options for measuring the current power.
- S0 pulse from an existing meter (min. 15 pulses/kWh)
- CT measurement using split-core current transformers (e.manager mc 2 only)
- Reading an existing meter via RS485 or LAN
- 4-20 mA signal (expansion required)
- Modbus TCP directly via the Enercon controller
Control
To control the wind turbine, the existing signals from the ripple control receiver are captured, combined with the setpoint from the direct marketer and then output to the wind turbine via the "e.digital OUT" module.
With an Enercon turbine, the power can be read directly via Modbus TCP. Control is also carried out directly via Modbus TCP.
Internet connection
A stable internet connection is required for the connection to the direct marketer, at least LTE speed.