RS485 + LAN
max. 32 devices per bus, max. 90 devices.
Power reduction
cos phi
RS485
If you use the inverters' SYM bus, please refer to the Kaco inverter manual. It shows many wiring variants.
Connect the inverters to each other.
e.manager terminal A <=> Kaco terminal B
e.manager terminal B <=> Kaco terminal A
Device address
Enter a unique address between 1 and 32 here.
Press both keys simultaneously.
Use key “1” to move to the next menu item. Use key “2” to change the settings.
Setting mode
Interface selection
RS485
Setting mode
RS485 address settings
LAN
SunSpec
Connect each inverter to the switch or router using a LAN cable.
Software version
Please make sure that the inverter has the latest software version, which also supports the SunSpec protocol.
IP address
The inverter requires a fixed IP address.
e.manager search
Select SunSpec in the search.