RS485 + LAN

max. 30 devices per bus, max. 90 devices.

Power reduction

cos phi

RS485

Piko inverters only

Hardware

 

Connect the inverters to each other.

e.manager terminal A <=> Kostal terminal 10 A
e.manager terminal B <=> Kostal terminal 9 B

Software

1. Web page

Each inverter has an internal web page for configuring the RS485 address.

  • Connect the inverter to the laptop.
  • Configure your laptop to obtain its network settings automatically.
  • Enter the following in your browser's address bar: http://Sxxxxxxxxxxxxxxxx
    replacing the “x” characters with the inverter's serial number.
  • When prompted for a password, enter the following:
    User name: pvserver
    Password: pvwr

2. Settings

On the overview page, you will find the “Settings” link at the bottom right

On the “Settings” page, enter a unique address between 1 and 99 in the “Inverter bus (RS485) address” field.

Click “Apply”

LAN

Piko, Plenticore, CI and KSEM three-phase meter

Hardware

Connect each inverter to the switch or router using a LAN cable.

Software

1. Web page

Each inverter has an internal web page for configuring the RS485 address.

  • Connect the inverter to the laptop using a crossover cable.
  • Configure your laptop to obtain its network settings automatically.
  • Enter the following in your browser's address bar: http://Sxxxxxxxxxxxxxxxx replacing the “x” characters with the inverter's serial number.
  • When prompted for a password, enter the following:
    User name: pvserver
    Password: pvwr

2. Settings

On the overview page, you will find the “Settings” link at the bottom right

On the “Settings” page, enter a unique address between 1 and 99 in the “Inverter bus (RS485) address” field.

Click “Apply”

3. Protocol

 Kostal inverters support various protocols.

  • Kostal protocol (on older inverters)
  • Modbus TCP 
  • SunSpec (select SunSpec in the search)