LAN + RS485
Power reduction
cos phi
RS485
Connect the inverters to each other using a patch cable.
Cut open the cable from the last inverter to the e.manager and connect the individual wires to the e.manager as follows.
e.manager terminal A <=> PIN 7 (brown-white)
e.manager terminal B <=> PIN 8 (brown)
Device address
Enter a unique address between 1 and 99 here.
Settings => Device address
Ethernet
Enter a unique address between 1 and 99 here.
Settings => Ethernet
LAN
With more than one inverter, the inverters are connected to each other via RS485. The last inverter is then connected to the e.manager via the LAN socket.
Connect the inverters to each other using a patch cable.
Connect the e.manager to the RS485/LAN socket of the last inverter using a patch cable.
Device address
Enter a unique address between 1 and 99 here.
Settings => Device address
Ethernet
Enter a unique address between 1 and 99 here.
IP address
Settings => Ethernet