RS485
Solarmax
RS485 Connection
Connect the inverters to each other with a patch cable.
Disconnect the cable from the last inverter to the e.manager and connect the individual lines to the e.manager as follows.
e.manager terminal A <=> PIN 7 (brown-white)
e.manager terminal B <=> PIN 8 (brown)
Inverter configuration
Please proceed as follows for each inverter.
1. Device address
Settings
Device address
Here please enter a unique address between 1 and 99.
2. Ethernet
Since the RS485 bus and the Ethernet use the same socket, it must be ensured that the Ethernet connection is switched off.
Settings
Ethernet
Please set the Ethernet off here.
LAN
Solarmax
RS485 und LAN Anschluss
Connect the inverters to each other with a patch cable.
Connect the data logger to the RS485/LAN socket of the first or last inverter using a patch cable.
Inverter configuration
Please proceed as follows for each inverter.
1. Device address
Settings
Device address
Please enter here a unique address between 1 and 99.
2. Ethernet
Since the RS485 bus and the Ethernet use the same socket it must be ensured that the Ethernet connection is switched off.
Settings
Ethernet
Please set the Ethernet off here.
Switch on the Ethernet at the first or last inverter.